	<item>
		<title>What You Need to Know About AWEF: New and Retrofit Installs</title>
		<link>https://k-rp.com/awef-faqs-new-retrofit-installs/</link>
		
		<dc:creator><![CDATA[webadmin]]></dc:creator>
		<pubDate>Mon, 22 Jun 2020 12:17:40 +0000</pubDate>
				<category><![CDATA[AWEF]]></category>
		<guid isPermaLink="false">https://pcs.k-rp.com/what-you-need-to-know-about-awef-new-and-retrofit-installs/</guid>

					<description><![CDATA[<p>While the new energy efficiency rules, commonly referred to as “AWEF”, have been in place since January 1, 2020, we are still receiving numerous questions surrounding<span class="excerpt-hellip"> […]</span></p>
<p>The post <a href="https://k-rp.com/awef-faqs-new-retrofit-installs/">What You Need to Know About AWEF: New and Retrofit Installs</a> appeared first on <a href="https://pcs.k-rp.com">KeepRite Refrigeration</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div>
<p class="p1"><span class="s1">While the new energy efficiency rules, commonly referred to as “AWEF”, have been in place since January 1, 2020, we are still receiving numerous questions surrounding the new regulations including whether the rules apply to new or retrofit installs. </span></p>
<p class="p1"><span class="s1">Staying true to Our Continued Commitment to the Refrigeration Professional, we are here to answer any and all of your AWEF questions. </span></p>
<p class="p1"><span class="s1">We have already established <a href="https://k-rp.com/awef-faqs-compliance/"><span class="s2">how to achieve compliance through AWEF standards</span></a> and who is responsible for ensuring products and equipment are compliant, but what about the equipment that is used for either new or retrofit installations? Is there a difference between the two when it comes to the effects of the AWEF regulations? </span></p>
<h2 class="p1"><span class="s1">What equipment has to be compliant?</span></h2>
<p class="p1"><span class="s1">According to <a href="https://www.nrcan.gc.ca/home"><span class="s2">NRCAN</span></a> and <a href="https://www.energy.gov/"><span class="s2">DOE’s</span></a> WICF ruling, the AWEF regulations apply to anyone manufacturing, producing, assembling or importing certified walk-in cooler and freezer components. </span></p>
<p class="p1"><span class="s1">In terms of commercial refrigeration, compliant components refer to dedicated and packaged condensing units, both indoor and outdoor, used in (and this is the important part) <b>both new and retrofit applications</b>. This includes the following:</span></p>
<ul class="ul1">
<li class="li1"><span class="s1">Condensing units that are assembled to construct a new walk-in cooler and freezer</span></li>
<li class="li1"><span class="s1">Condensing units to replace an existing, previously installed walk-in cooler and freezer component, otherwise known as a retrofit</span></li>
<li class="li1"><span class="s1">Condensing units used within packaged systems</span></li>
</ul>
<p class="p1"><span class="s1">In addition to the condensing units, unit coolers (<a href="https://k-rp.com/product-category/evaporators/"><span class="s2">evaporators</span></a>), doors, panels and lighting are also considered to be within the authority of the new AWEF regulations. </span></p>
<h2 class="p1"><span class="s1">Does the date apply to the date of install, sale, or manufacture of affected equipment?</span></h2>
<p class="p1"><span class="s1">The new regulations came into effect January 1, 2020. Therefore, the date applies to the manufacturing of the equipment, not the date of the sale or installation. </span></p>
<p class="p1"><span class="s1">While impacted parties must meet the applicable standards based on the date of manufacture, contractors and wholesalers can still use and stock condensing units that were manufactured before January 1, 2020. Any condensing units manufactured after January 1, 2020, whether it’s a new or retrofit installation, must comply with the new AWEF standards.</span></p>
<h2 class="p1"><span class="s1">So, does it matter if it’s a new install or retrofit?</span></h2>
<p class="p1"><span class="s1">The answer is no, it doesn’t matter because ultimately compliance is required on all new equipment for both retrofits and for new installations.</span></p>
<p class="p1"><span class="s1">The AWEF regulations have had broad impacts throughout the industry, from OEMs and wholesalers to contractors and end-users. Because the new standards impact both new and retrofit equipment, every segment of the commercial refrigeration supply chain has needed to understand its implications, including us. </span></p>
<p class="p1"><span class="s1">Whether you’re gearing up for a new or retrofit commercial refrigeration installation, make sure that all of your equipment is compliant under the 2020 AWEF regulations.</span></p>
<p class="p1"><span class="s1">If you’re unsure how to proceed with these new regulations and ensuring your commercial refrigeration equipment is AWEF compliant, KeepRite Refrigeration can help guide you in a number of ways. First off, be sure to check out our <a href="https://k-rp.com/awef-faq/"><span class="s2">AWEF FAQ</span></a> page for answers to other questions surrounding AWEF. In addition, feel free to call your <a href="https://k-rp.com/?page_id=211"><span class="s2">local sales representative</span></a> or our Small Condensing Units product specialists at 1-844-893-3222 ext. 521.</span></p>
<p class="p1"><strong><span class="s1">With a wide range of compliant products to choose from along with over 75 years of expertise, you can count on KeepRite Refrigeration to help you achieve compliance on all of your commercial refrigeration installations.</span></strong></p>
<p>The post <a rel="nofollow" href="https://k-rp.com/awef-faqs-new-retrofit-installs/">What You Need to Know About AWEF: New and Retrofit Installs</a> appeared first on <a rel="nofollow" href="https://k-rp.com/">KeepRite Refrigeration</a>.</p>
</div>
<p>The post <a href="https://k-rp.com/awef-faqs-new-retrofit-installs/">What You Need to Know About AWEF: New and Retrofit Installs</a> appeared first on <a href="https://pcs.k-rp.com">KeepRite Refrigeration</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>What You Need to Know About AWEF: Compliance</title>
		<link>https://k-rp.com/awef-faqs-compliance/</link>
		
		<dc:creator><![CDATA[webadmin]]></dc:creator>
		<pubDate>Tue, 26 May 2020 17:55:23 +0000</pubDate>
				<category><![CDATA[AWEF]]></category>
		<category><![CDATA[News]]></category>
		<guid isPermaLink="false">https://pcs.k-rp.com/what-you-need-to-know-about-awef-compliance/</guid>

					<description><![CDATA[<p>As we’re all well aware of by now, the Department of Energy (DOE) and Natural Resources Canada (NRCAN) implemented new energy efficiency rules, regularly referred to<span class="excerpt-hellip"> […]</span></p>
<p>The post <a href="https://k-rp.com/awef-faqs-compliance/">What You Need to Know About AWEF: Compliance</a> appeared first on <a href="https://pcs.k-rp.com">KeepRite Refrigeration</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div>
<p class="p1"><span class="s1">As we’re all well aware of by now, the <a href="http://energy.gov/"><span class="s2">Department of Energy</span></a> (DOE) and <a href="https://www.nrcan.gc.ca/home"><span class="s2">Natural Resources Canada</span></a> (NRCAN) implemented new energy efficiency rules, regularly referred to as “AWEF.” Since coming into effect on January 1, 2020 we have received a number of <a href="https://k-rp.com/awef-faq/">frequently asked questions</a> surrounding these new regulations, especially questions in regard to compliance. </span></p>
<p class="p1"><span class="s1">Staying true to <a href="https://k-rp.com/quality/">Our Continued Commitment to the Refrigeration Professional</a>, we are here to answer any and all of your AWEF questions. </span></p>
<h2 class="p1"><span class="s1">Achieving Compliance Through AWEF Standards</span></h2>
<p class="p1"><span class="s1">To evaluate the energy efficiency of a complete walk-in cooler and freezer (WICF) system, the DOE uses a metric called the <i>Annual Walk-In Energy Factor</i> (AWEF) created by the <a href="http://www.ahrinet.org/Home"><span class="s2">Air-Conditioning, Heating, and Refrigeration Institute (AHRI)</span></a>. </span></p>
<p class="p1"><span class="s1">According to AHRI, this calculation is based on “a ratio of the total heat, not including the heat generated by the operation of refrigeration systems, removed, in Btu, from a walk-in box during a one-year period of usage for refrigeration to the total energy input of refrigeration systems, in watt-hours, during the same period.”</span></p>
<p class="p1"><span class="s1">As mentioned in <a href="https://k-rp.com/category/awef/"><span class="s2">previous articles</span></a>, these regulations apply to WICFs smaller than 3,000 square feet. This includes a number of WICF product types that must meet or exceed the minimum AWEF ratings based on capacity and application. </span></p>
<p class="p1"><span class="s1">We know this is a lot to keep track of which is why we have put together the following table detailing the minimum AWEF rating per product type. </span></p>
<table class="t1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td class="td1" colspan="2" valign="top">
<p class="p3"><span class="s1"><b>Minimum AWEF Per Equipment Class</b></span></p>
</td>
</tr>
<tr>
<td class="td2" valign="top">
<p class="p3"><span class="s1"><b>Product Type</b></span></p>
</td>
<td class="td3" valign="top">
<p class="p3"><span class="s1"><b>Minimum AWEF (Btu/W-h)</b></span></p>
</td>
</tr>
<tr>
<td class="td2" valign="top">
<p class="p1"><span class="s1">Dedicated condensing system — medium, indoor</span></p>
</td>
<td class="td3" valign="top">
<p class="p1"><span class="s1">5.61</span></p>
</td>
</tr>
<tr>
<td class="td2" valign="top">
<p class="p1"><span class="s1">Dedicated condensing system — medium, outdoor</span></p>
</td>
<td class="td3" valign="top">
<p class="p1"><span class="s1">7.60</span></p>
</td>
</tr>
<tr>
<td class="td4" valign="top">
<p class="p1"><span class="s1">Dedicated condensing system — low, indoor with a net capacity (</span><span class="s3">q</span><span class="s4"><sub>net</sub></span><span class="s1">*) of:</span></p>
</td>
<td class="td5" valign="top"></td>
</tr>
<tr>
<td class="td2" valign="top">
<p class="p1"><span class="s1">&lt; 6,500 Btu/h</span></p>
</td>
<td class="td3" valign="top">
<p class="p1"><span class="s1">9.091 × 10-5 × </span><span class="s3">q</span><span class="s4"><sub>net</sub></span><span class="s1"> + 1.81</span></p>
</td>
</tr>
<tr>
<td class="td2" valign="top">
<p class="p1"><span class="s1">≥ 6,500 Btu/h</span></p>
</td>
<td class="td3" valign="top">
<p class="p1"><span class="s1">2.40</span></p>
</td>
</tr>
<tr>
<td class="td4" valign="top">
<p class="p1"><span class="s1">Dedicated condensing system — low, outdoor with a net capacity (</span><span class="s3">q</span><span class="s4"><sub>net</sub></span><span class="s1"> *) of:</span></p>
</td>
<td class="td5" valign="top"></td>
</tr>
<tr>
<td class="td2" valign="top">
<p class="p1"><span class="s1">&lt; 6,500 Btu/h</span></p>
</td>
<td class="td3" valign="top">
<p class="p1"><span class="s1">6.522 × 10-5 × </span><span class="s3">q</span><span class="s4"><sub>net</sub></span><span class="s1"> + 2.73</span></p>
</td>
</tr>
<tr>
<td class="td2" valign="top">
<p class="p1"><span class="s1">≥ 6,500 Btu/h</span></p>
</td>
<td class="td3" valign="top">
<p class="p1"><span class="s1">3.15</span></p>
</td>
</tr>
<tr>
<td class="td2" valign="top">
<p class="p1"><span class="s1">Unit cooler – medium</span></p>
</td>
<td class="td3" valign="top">
<p class="p1"><span class="s1">9.00</span></p>
</td>
</tr>
<tr>
<td class="td2" valign="top">
<p class="p1"><span class="s1">Unit cooler – low, with a net capacity (</span><span class="s3">q</span><span class="s4"><sub>net</sub></span><span class="s1">) of:</span></p>
</td>
<td class="td3" valign="top"></td>
</tr>
<tr>
<td class="td2" valign="top">
<p class="p1"><span class="s1">&lt; 15,500 Btu/h</span></p>
</td>
<td class="td3" valign="top">
<p class="p1"><span class="s1">1.575 × 10-5 × </span><span class="s3">q</span><span class="s4"><sub>net</sub></span><span class="s1"> + 3.91</span></p>
</td>
</tr>
<tr>
<td class="td2" valign="top">
<p class="p1"><span class="s1">≥ 15,500 Btu/h</span></p>
</td>
<td class="td3" valign="top">
<p class="p1"><span class="s1">4.15</span></p>
</td>
</tr>
</tbody>
</table>
<p class="p5"><span class="s5">*</span><span class="s6"> q</span><span class="s7"><sub>net</sub></span><span class="s6"> is net capacity as determined in accordance with Section 431.304 of Title 10 of the United States Code of Federal Regulations.</span></p>
<p class="p6"><span class="s3">**Resource: NRCAN (<a href="https://www.nrcan.gc.ca/walk-coolers-and-freezers/19543?wbdisable=true#wb-cont"><span class="s8">https://www.nrcan.gc.ca/walk-coolers-and-freezers/19543?wbdisable=true#wb-cont</span></a></span><span class="s5">)</span></p>
<h2 class="p7"><span class="s1">Who’s Responsible for Making Sure Products and Equipment Are Compliant?</span></h2>
<p class="p1"><span class="s1">It is the responsibility of the manufacturer to certify its equipment to be manufactured and sold as compliant. It is the responsibility of those assembling/installing the system to use certified equipment for retrofitting existing jobs and/or for new installations. This includes:</span></p>
<ul class="ul1">
<li class="li9"><span class="s1"><strong>Wholesalers/Salesperson/OEM:</strong> to ensure correct equipment is selected</span></li>
<li class="li9"><span class="s1"><strong>Contractors:</strong> to ensure equipment supplied is compliant</span></li>
</ul>
<h2 class="p1"><span class="s1">How is KeepRite Refrigeration Helping Wholesalers/OEMs/Contractors?</span></h2>
<p class="p1"><span class="s1">There are a variety of ways we are helping members within the WICF supply chain achieve compliance. </span></p>
<p class="p1"><span class="s1">As a manufacturer of <a href="https://k-rp.com/product-category/condensing-units/"><span class="s2">condensing units</span></a> for a wide range of commercial refrigeration applications, we are producing certified WICF condensing units that meet and exceed the DOE’s minimum AWEF requirements. </span></p>
<h2 class="p1"><span class="s1">Where Do I Find Specifications on KeepRite Refrigeration’s Compliant Products?</span></h2>
<p class="p1"><span class="s1">Our website always provides the most up-to-date product information available:</span></p>
<ul>
<li><span class="s6"><b>KEH “Generation D” Hermetic Air-cooled Condensing Units</b>:</span>
<ul>
<li class="p10"><span class="s5">Website: <a href="https://k-rp.com/product/keh-indooroutdoor-air-cooled-hermetic-condensing-units/"><span class="s11">k-rp.com/keh  </span></a> Product Specifications: <a href="https://docs.k-rp.com/1108864.pdf"><span class="s11">https://docs.k-rp.com/1108864.pdf</span></a></span></li>
</ul>
</li>
</ul>
<ul class="ul1">
<li class="li1"><span class="s6"><b>KEZ “Generation D” Scroll Air-cooled Condensing Units</b>:</span>
<ul class="ul1">
<li class="li1"><span class="s5">Website: <a href="https://k-rp.com/product/kez-indooroutdoor-air-cooled-scroll-condensing-units/"><span class="s11">k-rp.com/kez</span></a> Product Specifications: <a href="https://docs.k-rp.com/1108861.pdf"><span class="s11">https://docs.k-rp.com/1108861.pdf</span></a></span></li>
</ul>
</li>
</ul>
<ul class="ul1">
<li class="li1"><span class="s6"><b>KES “Generation D” Semi-hermetic Air-cooled Condensing Units</b>:</span>
<ul class="ul1">
<li class="li1">Website: <a href="https://k-rp.com/product/kes-indooroutdoor-air-cooled-semi-hermetic-condensing-units/"><span class="s11">k-rp.com/kes</span></a> Product Specifications: <a href="https://docs.k-rp.com/1108867.pdf"><span class="s11">https://docs.k-rp.com/1108867.pdf</span></a></li>
</ul>
</li>
</ul>
<p class="p11"><span class="s1">In addition, our KQ Quiet Condensing Units, KMS/KMD and KVS/KVD Condensing Units can also be used in applications requiring compliance:</span></p>
<ul class="ul1">
<li class="li1"><span class="s6"><b>KQ “Quiet” Scroll Condensing Units</b>:</span>
<ul class="ul1">
<li class="li1">Website: <a href="https://k-rp.com/product/kqz-outdoor-air-cooled-quiet-scroll-condensing-units/"><span class="s11">k-rp.com/kq</span></a> Product Specifications: <a href="https://docs.k-rp.com/1090650.pdf"><span class="s11">https://docs.k-rp.com/1090650.pdf</span></a></li>
</ul>
</li>
</ul>
<ul class="ul1">
<li class="li1"><span class="s6"><b>KMS/KMD Air-cooled Condensing Units</b>:</span>
<ul class="ul1">
<li class="li1">Website: <a href="https://k-rp.com/product/km-medium-outdoor-air-cooled-condensing-units/"><span class="s11">k-rp.com/km</span></a> Product Specifications: <a href="https://docs.k-rp.com/1092981.pdf"><span class="s11">https://docs.k-rp.com/1092981.pdf</span></a></li>
</ul>
</li>
</ul>
<ul class="ul1">
<li class="li1"><span class="s6"><b>KVS/KVD Air-cooled Condensing Units</b>:</span>
<ul class="ul1">
<li class="li1">Website: <a href="https://k-rp.com/product/kv-large-outdoor-air-cooled-condensing-units/"><span class="s11">k-rp.com/kv</span></a> Product Specifications: <a href="https://docs.k-rp.com/1073950.pdf"><span class="s11">https://docs.k-rp.com/1073950.pdf</span></a></li>
</ul>
</li>
</ul>
<h2 class="p1"><span class="s1">Can I Get Non-Compliant Equipment for an Exempted Application? </span></h2>
<p class="p1"><span class="s1">We will continue to offer legacy models for use where the new regulations are not required (subject to change based on market dynamics). Follow the links below to legacy model literature:</span></p>
<ul class="ul1">
<li class="li1"><span class="s6"><strong>KEH “C-Generation” Hermetic Air-cooled Condensing Units</strong>: <a href="https://docs.k-rp.com/1106701.pdf"><span class="s11">https://docs.k-rp.com/1106701.pdf</span></a></span></li>
<li class="li1"><span class="s6"><strong>KEZ “C-Generation” Scroll Air-cooled Condensing Units</strong>: <a href="https://docs.k-rp.com/1106738.pdf"><span class="s11">https://docs.k-rp.com/1106738.pdf</span></a></span></li>
<li class="li1"><span class="s6"><strong>KES “C-Generation” Semi-hermetic Air-cooled Condensing Units</strong>: <a href="https://docs.k-rp.com/1106704.pdf"><span class="s11">https://docs.k-rp.com/1106704.pdf</span></a></span></li>
</ul>
<h2 class="p1"><span class="s1">Do I Have to Be Compliant?</span></h2>
<p class="p1"><span class="s1">To sum up all of this information into one word, the answer is, yes. Yes, you do have to be compliant. </span></p>
<p class="p1"><span class="s1">If you’re unsure or think that you may be exempted from these regulations, we highly suggest purchasing a compliant unit anyways since they are more up-to-date and will perform better overall for your commercial refrigeration application.</span></p>
<p class="p1"><span class="s1">If you’re unsure how to proceed with these new regulations and ensuring your commercial refrigeration equipment is AWEF compliant, KeepRite Refrigeration can help guide you in a number of ways. First off, be sure to check out our <a href="https://k-rp.com/awef-faq/"><span class="s2">AWEF FAQ</span></a> page for answers to other questions surrounding AWEF. </span></p>
<p class="p1"><span class="s1">In addition, feel free to call your <a href="https://k-rp.com/?page_id=211"><span class="s2">local sales representative</span></a> or our Small Condensing Units product specialists at 1-844-893-3222 ext. 521.</span></p>
<p class="p1"><strong><span class="s1">With a wide range of compliant products to choose from along with over 75 years of expertise, you can count on KeepRite Refrigeration to help you achieve compliance.</span></strong></p>
<p>The post <a rel="nofollow" href="https://k-rp.com/awef-faqs-compliance/">What You Need to Know About AWEF: Compliance</a> appeared first on <a rel="nofollow" href="https://k-rp.com/">KeepRite Refrigeration</a>.</p>